Spectre Receives Best Review From SSCA
Note: In This Case, Lower is Better; Higher is Worse
|
|
|
![]() |
As Published in Cruising World Magazine Jan 2006 page 101
Data Provided by SSCA Member's Survey
|

Water Maker Controls
|
Function
|
![]() |
Water Quality Monitor
Dual Pump Control &
Backflush System
Pump Pressure and Product Water Production Rate Meter
|

Component
|
Info
|
Model
|
9680-C
|
System #
|
D9291A
|
Serial #
|
US00365055
|
H.W.
|
101
|
S.W.
|
55
|
50° F (10° C) Sea Water
|
77° F (25° C) Sea Water
|
90° F (32° C) Sea Water
|
|||||||||||
DC Voltage
|
Feed Flow
GPM (LPM)
|
Feed Pressure
|
Membrane Pressure
|
Product
GPH (LPH)
|
Amps
|
Feed Pressure
|
Membrane Pressure
|
Product
GPH (LPH)
|
Amps
|
Feed Pressure
|
Membrane Pressure
|
Product
GPH (LPH)
|
Amps
|
12.5
|
2.1
(7.9)
|
104
(7.0)
|
845
(57.5)
|
14.0
(53.0)
|
20.0
|
92
(6.2)
|
670
(45.6)
|
15.0
(56.8)
|
18.5
|
92
(6.2)
|
645
(43.9)
|
15.3
(57.9)
|
18.2
|
13.8
|
2.6
(9.8)
|
110
(7.5)
|
880
(59.8)
|
15.0
(56.8)
|
21.2
|
98
(6.6)
|
700
(47.6)
|
16.5
(62.4)
|
19.6
|
98
(6.6)
|
665
(45.2)
|
17.0
(64.3)
|
19.1
|
14.4
|
2.7
(10.2)
|
112
(7.6)
|
900
(61.2)
|
15.5
(57.8)
|
21.5
|
102
(6.9)
|
710
(48.3)
|
17.0
(64.3)
|
20.0
|
100
(6.8)
|
675
(45.9)
|
17.5
(66.2)
|
19.5
|
Unit
|
Model
|
S/N
|
Date
|
Extra
|
Clark Pump
|
6/2002
|
|||
TDS Controller
|
HI 983329
|
6108X
|
9/2002
|
2/2003
|
Membrane
|
6/2001
|
|||
Membrane End Caps
|
9/2002
|
|||
Salinity Sensor
|
9/2002
|
2/2003
|
||
Reject Water Bypass Valve
|
6/2002
|
2/2003
|
||
Control Head
|
9/2002
|
2/2003
|
||
Pump 1
|
6/2001
|
|||
Pump 2
|
6/2001
|
Recommended Spares - Essential & Nice-to-have
|
Essential
Check Valve Seat Qty 4 # CP00011CVS
Check Valve Seat O rings Qty 4 # 2-018N70
Check Valve Poppet Qty 4 # CP00013CVP
Check Valve Washer Qty 4 # CP00013CVW
Check Valve Spring Qty 4 # CP00013CVS
Check Valve Retainer Qty 4 # CP00012CVR
Check Valve Port O ring Qty 4 # 2-020V894-90
Annular Ring Qty 2 # CP00014AR
Annular Ring O ring Qty 4 # 2-124V894-90
Nice to have
Pilot Valve Spool Qty 1 # CP00010PVS
Pilot Valve Spool O rings Qty 4 # 2-111 N1090-85
Pilot Valve Pin Qty 2 # CP0008PVP
Pilot Valve Pin Seal Qty 2 # CP0007PVPS
Pilot Valve Pin Seal O rings Qty 2 # 2-013N70
Pilot Seal/Piston Poppet clip ring Qty 2 # CP0009PVCR
Valve Spool Seal Qty 2 # CP00017RVSS
Valve Spool Quad ring Qty 2 # Q4-208-BN
Valve Spool Piston O rings Qty 4 # 2-218S604-70
Valve Bore O ring Qty2 # 2-029N70
Courtesy of Chas on Night Owl
|
Spares Carried on Dakare (5/2004)
|
June 2005
|
Dan: The SC-1 chemical is good for at least 6 months. If the unit is to be stored for long periods you may find it better to use Propylene Glycol Potable Water System Antifreeze which is good for a year. A lot depends on the temperature the system is stored at and how clean the system is. Thanks, Dean
|
Sept 2008
|
... if one of your Shurflo pumps is turning on and off, then you’re pressure switch is set incorrectly. There is a 5/64” allen screw on the base of the pump that sets the cut-out pressure. They should be set to 125 PSI, if the pump is turning off before that pressure, then try tightening that set screw (clockwise increases the pressure, counter clockwise decreases it). Hope this helps.
Kyle Stephan
Spectra Watermakers
20 Mariposa Rd
San Rafael, CA 94901
Tel: 415-526-2780
Fax: 415-526-2787
kyle_s@spectrawatermakers.com
|
Date
|
PPM
|
Sept 2002
|
325
|
Oct 2003
|
352
|
May 2004
|
285
|
Aug 2005
|
355
|
Sept 2006
|
390
|
Sept 2008
|
350
|